Saturday, 14 September 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 48

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 48



1. Clear fault memory



2. Ignition off, allow vehicle to assume complete dormant



status



3. Ignition on



4. Read out stored fault codes from fault memory



Fault effect and breakdown warning



Driver information



Warning light:



none



Service instruction



none



2AB5



2AB5 - P16A4



Information saved in



DME



Fault code



2AB5 - P16A4



Fault text



DME, internal fault: knock-sensor module



Fault description



Timeout Control Module Knock Sensor SPI-Bus



Condition for fault identification



Test condition:



Monitoring of knock sensor chip



Engine speed >320 rpm



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



Yes, by event counter. Fault must occur ten times before a



fault memory entry is made.



Action in service



Determine whether fault is stored again after carrying out



the following procedure. If yes: Replace DME.



1. Clear fault memory



2. Ignition off, allow vehicle to assume complete dormant



status



3. Ignition on



4. Read out stored fault codes from fault memory



Fault effect and breakdown warning