MRS III - Diagnosis Seemingly Not possible
Group 09
Programming/Coding Explanations
Bulletin Number
09 02 99
Woodcliff Lake, NJ
April 1999
Product Engineering
This bulletin is also issued in Group 72 (Safety Restraint Systems), S.I. bulletin 72 06 99, the contents of which are identical.
SUBJECT:
E39 MRS III Diagnosis
MODEL:
E39
Situation:
266
MRS III diagnosis is seemingly not possible on E39s produced 3/99 and later with CD17 or earlier (16.1,16.0, etc.).
Cause:
CD17 software error
Vehicles Affected:
E39 produced 3/99 and later(MRS III)
Correction:
Using CD17 only, manually identify the vehicle as a 3/99 USA E38 and proceed with the normal diagnosis.
Software with be corrected in CD18.