Showing posts with label Emissions System - Evaporative System Leak Testing. Show all posts
Showing posts with label Emissions System - Evaporative System Leak Testing. Show all posts

Wednesday, 2 January 2019

Emissions System - Evaporative System Leak Testing

2010 BMW 335Cic Convertible (E93) L6-3.0L Turbo (N54) Technical Service Bulletin # 160107 Date: 110901



Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



2010 BMW 335Cic Convertible (E93) L6-3.0L Turbo (N54) 101



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



2010 BMW 335Cic Convertible (E93) L6-3.0L Turbo (N54) 102



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 335Cic Convertible (E93) L6-3.0L Turbo (N54) 103



[NEW] WARRANTY INFORMATION

Thursday, 27 December 2018

2010 BMW M6 Convertible (E64) V10-5.0L (S85)DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



2010 BMW M6 Convertible (E64) V10-5.0L (S85) Page 74



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



2010 BMW M6 Convertible (E64) V10-5.0L (S85) Page 75



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



2010 BMW M6 Convertible (E64) V10-5.0L (S85) Page 76



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



[NEW] WARRANTY INFORMATION

Wednesday, 26 December 2018

2010 BMW M5 (E60) V10-5.0L (S85)DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



2010 BMW M5 (E60) V10-5.0L (S85) Page 74



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



2010 BMW M5 (E60) V10-5.0L (S85) Page 75



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



2010 BMW M5 (E60) V10-5.0L (S85) Page 76



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



[NEW] WARRANTY INFORMATION

Friday, 7 December 2018

2010 BMW 135i Convertible (E88) L6-3.0L Turbo (N54)DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



2010 BMW 135i Convertible (E88) L6-3.0L Turbo (N54) Page 116



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 135i Convertible (E88) L6-3.0L Turbo (N54) Page 117



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 135i Convertible (E88) L6-3.0L Turbo (N54) Page 118



[NEW] WARRANTY INFORMATION

Tuesday, 4 December 2018

BMW 528i (E60) L6-3.0L (N52K) Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



2010 BMW 528i (E60) L6-3.0L (N52K) Page 94



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



2010 BMW 528i (E60) L6-3.0L (N52K) Page 95



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



2010 BMW 528i (E60) L6-3.0L (N52K) Page 96



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



[NEW] WARRANTY INFORMATION

Monday, 3 December 2018

2010 BMW 750Li xDrive AWD (F02) V8-4.4L Turbo (N63)DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



2010 BMW 750Li xDrive AWD (F02) V8-4.4L Turbo (N63) Page 127



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



2010 BMW 750Li xDrive AWD (F02) V8-4.4L Turbo (N63) Page 128



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 750Li xDrive AWD (F02) V8-4.4L Turbo (N63) Page 129



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 750Li xDrive AWD (F02) V8-4.4L Turbo (N63) Page 130



[NEW] WARRANTY INFORMATION

Thursday, 29 November 2018

2010 BMW 750i (F01) V8-4.4L Turbo (N63)DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



2010 BMW 750i (F01) V8-4.4L Turbo (N63) Page 127



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



2010 BMW 750i (F01) V8-4.4L Turbo (N63) Page 128



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 750i (F01) V8-4.4L Turbo (N63) Page 129



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 750i (F01) V8-4.4L Turbo (N63) Page 130



[NEW] WARRANTY INFORMATION

Wednesday, 28 November 2018

2010 BMW M3 Sedan (E90) V8-4.0L (S65) DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



2010 BMW M3 Sedan (E90) V8-4.0L (S65) Page 82



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



2010 BMW M3 Sedan (E90) V8-4.0L (S65) Page 83



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW M3 Sedan (E90) V8-4.0L (S65) Page 84



[NEW] WARRANTY INFORMATION

Friday, 23 November 2018

2010 BMW 535xi Wagon AWD (E61) L6-3.0L Turbo (N54) DIAGNOSIS AND REPAIR, MAINTENANCE,Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



2010 BMW 535xi Wagon AWD (E61) L6-3.0L Turbo (N54) Page 184



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



2010 BMW 535xi Wagon AWD (E61) L6-3.0L Turbo (N54) Page 185



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 535xi Wagon AWD (E61) L6-3.0L Turbo (N54) Page 186



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 535xi Wagon AWD (E61) L6-3.0L Turbo (N54) Page 187



[NEW] WARRANTY INFORMATION

Wednesday, 21 November 2018

2010 BMW 750i xDrive AWD (F01) V8-4.4L Turbo (N63) DIAGNOSIS AND REPAIR, MAINTENANCE,Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



2010 BMW 750i xDrive AWD (F01) V8-4.4L Turbo (N63) Page 127



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



2010 BMW 750i xDrive AWD (F01) V8-4.4L Turbo (N63) Page 128



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 750i xDrive AWD (F01) V8-4.4L Turbo (N63) Page 129



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 750i xDrive AWD (F01) V8-4.4L Turbo (N63) Page 130



[NEW] WARRANTY INFORMATION

Sunday, 18 November 2018

2010 BMW 128i Convertible (E88) L6-3.0L (N51) DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



2010 BMW 128i Convertible (E88) L6-3.0L (N51) Page 116



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 128i Convertible (E88) L6-3.0L (N51) Page 117



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 128i Convertible (E88) L6-3.0L (N51) Page 118



[NEW] WARRANTY INFORMATION

Thursday, 15 November 2018

2010 BMW 760Li (F02) V12-6.0L Turbo (N74) DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



2010 BMW 760Li (F02) V12-6.0L Turbo (N74) Page 119



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



2010 BMW 760Li (F02) V12-6.0L Turbo (N74) Page 120



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



2010 BMW 760Li (F02) V12-6.0L Turbo (N74) Page 121



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 760Li (F02) V12-6.0L Turbo (N74) Page 122



[NEW] WARRANTY INFORMATION

Sunday, 11 November 2018

2010 BMW 650i Convertible (E64) V8-4.8L (N62TU) DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



2010 BMW 650i Convertible (E64) V8-4.8L (N62TU) Page 88



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



2010 BMW 650i Convertible (E64) V8-4.8L (N62TU) Page 89



Hose Connection to DMTL



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



2010 BMW 650i Convertible (E64) V8-4.8L (N62TU) Page 90



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



[NEW] WARRANTY INFORMATION

Monday, 5 November 2018

2010 BMW 328Cic Convertible (E93) L6-3.0L (N52K) DIAGNOSIS AND REPAIR, MAINTENANCE, DIAGNOSIS AND Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



2010 BMW 328Cic Convertible (E93) L6-3.0L (N52K) Page 98



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



2010 BMW 328Cic Convertible (E93) L6-3.0L (N52K) Page 99



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW 328Cic Convertible (E93) L6-3.0L (N52K) Page 100



[NEW] WARRANTY INFORMATION

Thursday, 1 November 2018

2010 BMW M3 Coupe (E92) V8-4.0L (S65) DIAGNOSIS AND REPAIR, MAINTENANCE, Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



2010 BMW M3 Coupe (E92) V8-4.0L (S65) Page 84



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



2010 BMW M3 Coupe (E92) V8-4.0L (S65) Page 85



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW M3 Coupe (E92) V8-4.0L (S65) Page 86



[NEW] WARRANTY INFORMATION

Monday, 29 October 2018

2010 BMW M3 Convertible (E93) V8-4.0L (S65) DIAGNOSIS AND REPAIR, MAINTENANCE,Technical Service Bulletin # 160107 Date: 110901


Emissions System - Evaporative System Leak Testing



SI B16 01 07



Fuel Supply Systems



September 2011



Technical Service



This Service Information bulletin supersedes SI B16 01 07 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



Testing Evaporative Systems for Leaks



MODEL



All



[NEW] EVAP SYSTEM TANK LEAKAGE DMTL TEST MODULE OPERATING HINTS



Evaporative system leakage is found using the DMTL tank leakage test plan:



If a leakage is found to be present using the DMTL leakage test plan, the following points should be verified.



1. Check that the fuel cap is properly closed.



2. Testing the evaporative system requires all venting pipes and electrical connectors to be properly connected.



3. Search for leakage; if needed, use the VACUTEC(R) Smoke Machine 625-522B-BMW.



4. Do not replace the DMTL pump or fuel cap.



Evaporative system leakage is NOT found using the DMTL tank leakage test plan:



Only perform the applicable test plans for the faults stored. Performing additional leak measurements using a smoke machine on a vehicle that



does not fail the DMTL leakage test plan will not be reimbursed by Warranty. Do not replace the fuel cap, DMTL pump or carbon canister.



DMTL pump "system error" fault is stored in the vehicle:



Only perform the applicable test plan for the fault stored. If the test plan states to replace the DMTL pump, only replace that component.



^ Do not smoke test the vehicle.



^ Do not replace the fuel cap.



^ Do not drain the fuel tank or refill.



TROUBLESHOOTING HINTS WHEN USING THE VACUTEC SMOKE MACHINE



Testing evaporative systems for leaks is very challenging. We have developed some diagnostic hints, along with the introduction of a new special



tool, to properly connect a smoke machine to the DMTL



fresh air vent/filter connection.



Recently the VACUTEC(R) Smoke Machine 625-522B-BMW was added to the BMW Equipment Program. The VACUTEC(R) Smoke Machine



625-522B-BMW is the only approved testing device for the fuel and evaporative systems. This device automatically converts air to high purity



2010 BMW M3 Convertible (E93) V8-4.0L (S65) Page 80



nitrogen, using Pressure Swing Absorption (PSA) nitrogen technology. Orders for the VACUTEC(R) Smoke Machine 625-522B-BMW, can be



placed by calling the BMW Equipment program.



[NEW] Included with the new VACUTEC(R) smoke machine are various caps and adaptors to help connect the applicator hose to the vehicle. It is



always suggested not to disturb the system before testing; try to create as little disturbance as possible to the system when connecting the smoke



machine. This smoke machine utilizes an UltraTraceUVF smoke solution. The smoke solution incorporates an ultraviolet dye, which helps pinpoint



the leak with an ultraviolet residue surrounding the leak area. Determining the source of the leak is made easy when the included Hi-Density True



UV LED light and incandescent white light are used.



[NEW] When testing the vehicle's evaporative system using the flow meter on the VACUTEC smoke machine, the ball indicator should not lift from



the zero measurement on the scale when the system is leak-free. All BMWs are designed to be 100% leak-free. A flow meter indicating zero flow



would be the same as placing your finger over or kinking the application hose of the VACUTEC smoke machine (no flow = 100% leak-free).



For more information regarding evaporative system testing, describing possible fire hazards using oxygen vs. nitrogen, please refer to the following



SAE web site:



www.sae.org/technical/papers/2007-01-1235



Shown below is the Evaporative Test Adaptor, which can connect directly to DMTL (Diagnosis Module Tank Leakage) pump-equipped vehicles



only after the fresh air filter connection has been removed. When properly connecting the tool to the system, the main benefit is that it does not



disturb the integrity of the system. This tool should be used anytime the vehicle is in the workshop for a small or large leak in the evaporative



system. Shown in the picture is the tool connected to the DMTL at the fresh air filter connection.



Evaporative Test Adapter



(for vehicles equipped with a DMTL pump) P/N 83 30 0 433 207



Hose Connection to DMTL



2010 BMW M3 Convertible (E93) V8-4.0L (S65) Page 81



When properly connecting the tool to the system, the main benefit is that it does not disturb the intergrity of the system. This tool should be used



anytime the vehicle is in the workshop for a small or large leak in the tool connected to the DMTL at the fresh air filter connections.



All vehicles equipped with a LDP (Leak Diagnosis Pump) system



Vehicles equipped with the LDP system will require a series of small pieces of rubber hose to adapt the smoke machine application hose.



NOTE:



It is important that the initial test of the system is conducted with the system intact; avoid disturbance of the system. All electrical connectors and



ventilation pipes should not be disturbed, because an intermittent issue could be disturbed and nothing will be found during the test plan. Electrical



connector seals and pin or socket grommets are important parts of the system's integrity; each component relies on the electrical connectors for



proper sealing. Removing these connectors during testing will result in an incorrect diagnosis of the system.



2010 BMW M3 Convertible (E93) V8-4.0L (S65) Page 82



[NEW] WARRANTY INFORMATION