2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 49

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 49



2AB6 - P16A5



Fault text



DME, internal fault: multiple output-stage module



Fault description



Timeout Control Module Multiple Output Stage SPI-Bus



Condition for fault identification



Test condition:



Driver circuit monitor



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



Yes, by event counter. Fault must occur ten times before a



fault memory entry is made.



Action in service



Determine whether fault is stored again after carrying out



the following procedure. If yes: Replace DME.



1. Clear fault memory



2. Ignition off, allow vehicle to assume complete dormant



status



3. Ignition on



4. Read out stored fault codes from fault memory



Fault effect and breakdown warning



Driver information



Warning light:



No warning message. No control activation possible from



some DME output terminals.



Service instruction



none



2ACB - P0686 (DME)



2ACB - P0686



Information saved in



DME



Fault code



2ACB - P0686



Fault text



DME master relay, activation



Fault description



ECM/PCM Power Relay Control Circuit Low



Condition for fault identification



Test condition:



Main relay monitoring



Main relay must have opened.



Terminal condition: First Terminal 15 OFF



(wait until main relay opens)



then Terminal 15 ON



(and leave ON)



Voltage condition:



Voltage in onboard electrical system > 10 V



Condition for fault memory entry