Sunday, 15 September 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 66

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 66



DME



Fault code



2A3A - P1041



Fault text



Valvetronic, internal fault



Fault description



Internal VVT-Control Module EEPROM Error (Bank 1)



Condition for fault identification



Test condition:



E2PROM fault



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



Fault set immediate without debounce



Action in service



Ignition off, wait for control module to return to dormant



"sleep" state, run travel limit initialization routine again or



trigger travel limit initialization routine manually



Fault effect and breakdown warning



Driver information



Warning light:



Limp-home operation 1



Service instruction



none



2A3C



2A3C - P1057



Information saved in



DME



Fault code



2A3C - P1057



Fault text



Valvetronic relay, activation



Fault description



VVT-Supply Voltage Control Motor Electrical (Bank 1)



Condition for fault identification



Test condition:



The voltage at the capacitors is monitored. If this is below



an offset of the battery voltage an fault symptom is



registered



Terminal condition: Main relay ON



Voltage condition:



none



Condition for fault memory entry



0.05



Action in service



1. Ignition off, let control module return to dormant state as



indicated, restart



2. If Item 1 is not OK, it will be necessary to check the



electronics in the control module