Friday, 6 September 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 125

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 125



Fault description



Throttle Valve Actuator Start Test Re-Adaptation Required



Condition for fault identification



Test condition:



Switch terminals



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system >= 10 V



Condition for fault memory entry



1 sec.



Action in service



1) Note collateral issues related to initial adaptation,



2) Check: The sum of throttle valve voltages must equal 5



V,



3) Perform electrical check on wiring to throttle valve



sensors and throttle valve motor, visual inspection of plug-in



contacts (at component, wiring harness and DME),



4) Replace component



Fault effect and breakdown warning



Driver information



Warning light:



CC status report: Reduced engine performance!,



MIL ON



EMB + rpm limit 1300 rpm



Service instruction



none



2CFE



2CFE - P1635



Information saved in



DME



Fault code



2CFE - P1635



Fault text



Throttle valve, continuous adaptation



Fault description



Throttle Valve Adaptation Lower Mechanical Stop not



Adapted (Bank 1)



Condition for fault identification



Test condition:



none



Terminal condition: none



Voltage condition:



none



Condition for fault memory entry



none



Action in service



none