2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 140

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 140



Condition for fault memory entry



Self-diagnosis processor chip has short to positive



Action in service



1. Visual inspection of wires, DME plug and O2 sensor for



damage



2. Check wires



3. Check plug-in connections DME <=> Wiring harness



<=> Upstream (pre-cat) O2 sensor for Bank 2



4. Check wiring harness for shorts to positive or ground and



shorts/shunt to other bank (melted?) => Replace wiring



harness



5. Replace O2 sensor



6. Replace DME



Fault effect and breakdown warning



Driver information



Warning light:



MIL ON



Service instruction



none



2C6A



2C6A - P0041



Information saved in



DME



Fault code



2C6A - P0041



Fault text



Oxygen sensors behind catalytic converter, mixed up



Fault description



O2 Sensor Signals Swapped Bank 1 Sensor 2 / Bank 2



Sensor 2



Condition for fault identification



Test condition:



O2 sensor system check



O2 sensor voltage too low = Signal sticks at lean on one



bank and O2 sensor voltage too high = Signal sticks on rich



on the other bank



The trim controller diagnosis must have been executed, see



trim controller diagnosis. Detection of faults during the trim



control diagnosis triggers the active test. Engine running at



idle is adequate for the active test;



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



Downstream (post-cat) O2 sensor voltage < 0.2 V with rich



lambda specification in active test for one bank, and



downstream (post-cat) O2 sensor voltage > 0.7 V with lean



lambda specification in active test on the other bank



Action in service



Replace downstream (post-cat) O2 sensors



Fault effect and breakdown warning