2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 142

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 142



Fault code



2C6B - P2271



Fault text



Oxygen sensor behind catalytic converter, system check



Fault description



O2 Sensor Signal Biased/Stuck Rich (Bank 1 Sensor 2)



Condition for fault identification



Test condition:



O2 sensor system check



O2 sensor voltage too low = Signal sticks on lean



Trim controller diagnosis must have been executed, see



Trim controller diagnosis. Detection of faults during the trim



control diagnosis triggers the active test. Engine running at



idle is adequate for the active test;



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



O2 sensor behind catalytic converter voltage < 0.2 V with



rich data specification for active test



Action in service



This malfunction is detected during the active test. The



active test is triggered by the trim control diagnosis function



(trim controller fault code stored in the control module's



fault memory!)



1. Initiate system test for reversed O2 sensors. Follow



instructions for system test.



2. If the system test fails to produce a result then



3. Visual inspection of wiring and plugs



4. Electrical check of wiring



5. Replace wires or plugs as indicated



6. Check exhaust system upstream from downstream (postcat)



O2 sensor for leaks



7. Replace downstream (post-cat) O2 sensor



8. Replace upstream (pre-cat) O2 sensor



9. Replace control module



Fault effect and breakdown warning



Driver information



Warning light:



MIL ON



Service instruction



none



2C6C - P2272 (DME)



2C6C - P2272



Information saved in



DME



Fault code



2C6C - P2272



Fault text



Oxygen sensor behind catalytic converter 2, system check



Fault description



O2 Sensor Signal Biased/Stuck Lean (Bank 2 Sensor 2)



Condition for fault identification