Saturday, 10 August 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 240

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 240



Driver information



Warning light:



none



Service instruction



none



2E7C



2E7C - P16C6



Information saved in



DME



Fault code



2E7C - P16C6



Fault text



Bit-serial data interface, signal



Fault description



CAN Timeout BSD (Bit Serial Data Interface)



Condition for fault identification



Test condition:



BSD bus monitor



Terminal condition: Terminal 15 ON



Voltage condition:



Terminal 87 >10.0 V



Condition for fault memory entry



Via event counter.



Total failure between BSD bus and all components (water



pump, oil sensor, alternator, battery sensor over



approximately 3 sec.



Action in service



1. Disconnect all BSD_components (alternator, battery



sensor, water pump) except for the oil sensor. Clear fault



memory. Ignition off/on. If fault code is stored again: QLT



is defective and must be replaced. Repeat test.



2. If fault code is entered again after QLT replacement: ->



Check wiring harness (BSD_BUS) and all plug-in



connections for corrosion and shorts to ground/UBatt.



3. If fault code no longer appears after QLT replacement: ->



QLT was defective.



4. If no fault code is stored after all components (except



QLT, as in 1.) are disconnected: -> The fault lies with one of



the other BSD_components. Now connect the water pump



and clear all fault memories, ignition off/on.



5. If no fault code is entered now, with the water pumpand



QLT connected -> Connect alternator.



6. If no fault code is stored with water pump, QLT and



alternator connected -> Connect battery sensor.



7. If the system now operates with all BSD components, and



no fault has been detected, recheck the plug connections in



the wiring harness and at the components for good contact /



corrosion.



Fault effect and breakdown warning



Driver information



Warning light:



No oil level display/no oil temperature display available.



Service interval calculations for next visit are based on



model. Water pump runs at 100 % cooling capacity and



draws continuous current of approximately 15A.