2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 218
MIL OFF EML ON CC: Power loss, engine malfunction
Service instruction
none
2D67 - P0605 (DME)
2D67 - P0605
Information saved in
DME
Fault code
2D67 - P0605
Fault text
DME, internal fault: monitoring, processors
Fault description
Internal Control Module Read Only Memory (ROM) Error
Condition for fault identification
Test condition:
Internal control-module fault, read memory processor fault
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
immediately
Action in service
Ensure that correct softare and data have been flashprogrammed;
repeat flash-programming as indicated. If
frequency > 3 Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL OFF EML ON CC: Power loss, engine malfunction
Service instruction
none
2D67 - P0606 (DME)
2D67 - P0606
Information saved in
DME
Fault code
2D67 - P0606
Fault text
DME, internal fault: monitoring, processors
Fault description
ECM/PCM Processor
Condition for fault identification
Test condition:
Internal control-module fault, general processor fault
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry