2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 289

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 289



Condition for fault identification



Test condition:



Time after end of start phase > 120 sec.



> 24 sec. (provisional data content definition),



engine must be running



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system > 10 V



Condition for fault memory entry



5 sec.



Action in service



1) Perform electrical check on sensor wire and power-supply



wires



2) Visual inspection of plug-in contacts (on component and



DME ends) 3) Replace sensor



Fault effect and breakdown warning



Driver information



Warning light:



MIL ON in US versions only



Service instruction



none



2F8F



2F8F - P2299



Information saved in



DME



Fault code



2F8F - P2299



Fault text



Accelerator pedal module and brake pedal, plausibility



Fault description



Brake Pedal Position / Accelerator Pedal Position



Incompatible



Condition for fault identification



Test condition:



Accelerator pedal module and brake pedal plausibility



monitor



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



1.5 sec.



Action in service



1) Discuss driving habits with customer (driving with both



feet)



2) Visual and operational check on PWG



Fault effect and breakdown warning