Saturday, 24 August 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 217

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 217



Fault description



Control Module Self-Test, Torque Monitoring Current



Indicated Value Plausibility



Condition for fault identification



Test condition:



Throttle valve not without current



Driver torque demand is being exceeded



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system >= 10 V



Condition for fault memory entry



480 ms



Action in service



Check mass airflow system (vacuum leaks, VVT, VANOS,



throttle valve...)



If frequency is >=3 Replace DME



Fault effect and breakdown warning



Driver information



Warning light:



MIL OFF EML ON CC: Reduced power, engine



malfunction



RPM limited to 1300 rpm



Service instruction



none



2D67 - P0604 (DME)



2D67 - P0604



Information saved in



DME



Fault code



2D67 - P0604



Fault text



DME, internal fault: monitoring, processors



Fault description



Internal Control Module Random Access Memory (RAM)



Error



Condition for fault identification



Test condition:



Internal control-module fault, RAM processor fault



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system >= 10 V



Condition for fault memory entry



immediately



Action in service



Ensure that correct softare and data have been flashprogrammed;



repeat flash-programming as indicated. If



frequency > 3 Replace DME



Fault effect and breakdown warning