Mass airflow exceeds 10 kg/h



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



Bank 2 downstream (post-cat) O2 sensor voltage less than



0.02 V; internal resistance in circuit for downstream oxygen



sensor less than 10 ohms



Action in service



1. Check wiring



2. Check plugs



3. Resistance measurement



4. Measure voltage



5. Replace Bank 2 downstream (post-cat) O2 sensor



Fault effect and breakdown warning



Driver information



Warning light:



MIL ON



Service instruction



none



2C77



2C77 - P0140



Information saved in



DME



Fault code



2C77 - P0140



Fault text



Oxygen sensor behind catalytic converter, signal



Fault description



O2 Sensor Circuit No Activity Detected (Bank 1 Sensor 2)



Condition for fault identification



Test condition:



O2 sensor signal test



No fault memories



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



O2 sensor voltage between 0.4 V and 0.5 V;



internal resistance in downstream oxygen sensor's circuit



exceeds 60 kOhms



Action in service



1. Visual inspection of wiring and plugs



2. Measure resistance



3. Replace affected wire



4. Replace wiring harness



5. Replace O2 sensor



Fault effect and breakdown warning