Sunday, 11 August 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 276

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 276



Information saved in



DME



Fault code



2FA4 - P3235



Fault text



Incorrect data record



Fault description



Control Module Monitoring Version Coding Plausibility



Condition for fault identification



Test condition:



Always active



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



none



Action in service



Data programming, of fault remains active re-enter DME



code, if then still active replace the DME



Fault effect and breakdown warning



Driver information



Warning light:



Reduced output



Service instruction



none



2F0D - P300A (DME)



2F0D - P300A



Information saved in



DME



Fault code



2F0D - P300A



Fault text



Radiator blind, activation, (GLF)



Fault description



Controlled Air Guiding Circuit High



Condition for fault identification



Test condition:



AKKS must be initialized.



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system > 10 V



Condition for fault memory entry



up to 20 sec.



Action in service



1. Check wire from the DME to the AKKS



Fault effect and breakdown warning