Monday, 12 August 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 97

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 97



beyond the warning threshold this fault code is entered.



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



Always active when DME is awake



VVT motor temperature: Warning threshold 190 锟斤拷C



Action in service



1. Check VVT servo motor



2. Allow engine to cool, let vehicle return to dormant state,



Clear fault memory and verify that DME has most recent



software version



Fault effect and breakdown warning



Driver information



Warning light:



ECE: No warning message. Engine reverts to VVT



emergency backup mode (throttled operation) US: OPEN



Service instruction



none



2A43 - P107C (DME)



2A43 - P107C



Information saved in



DME



Fault code



2A43 - P107C



Fault text



Valvetronic, thermal overload protection: warning threshold



Fault description



VVT-Overload Protection Temperature Too High



Condition for fault identification



Test condition:



The temperature of the VVT driver circuit in the DME is



monitored, and the system responds to overheating by



reverting to VVT emergency mode operation - the vehicle



continues to operate, but in throttled mode. Incorrect use of



the pedal-position sensor, consisting of rapid, repeated



pressure extending over several minutes heats up the VVT



driver circuit in the DME, leading to its deactivation when it



reaches a critical level.



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



after Terminal 15 switch and/or always active if DME is



awake.



VVT driver circuit in the DME: Warning threshold 112 锟斤拷C



Action in service



If no tampering/abuse can be detected the following tests



should be carried out:



1. Check for correct reluctor attachment at VVT sensor.



2. Use tester to manually activate the E-box fan for acoustic



check.



3. DME installed according to specification and check to



verify installation of spacer plate (to guide airflow in EBox).