Thursday, 11 July 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 188

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 188



Fault description



Fuel Level Signal 2



Condition for fault identification



Test condition:



Short circuit or open circuit in left-side level sensor, sensor



resistance too low/high



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



90 sec.



Action in service



Check sensor resistance, determine location of open wire /



short circuit (wiring harness, plug, cluster, junction box,



tank)



Fault effect and breakdown warning



Driver information



Warning light:



NO



Service instruction



none



2DE2 - P0462 (DME)



2DE2 - P0462



Information saved in



DME



Fault code



2DE2 - P0462



Fault text



Tank fill level, right, signal



Fault description



Fuel Level Sensor 'A' Circuit Low



Condition for fault identification



Test condition:



Right level sensor shorted, sensor resistance too low



Terminal condition: Terminal 15, engine on



Voltage condition:



none



Condition for fault memory entry



90 sec.



Action in service



Check sensor resistance, determine location of open wire /



short circuit (wiring harness, plug, cluster, junction box,



tank)



Fault effect and breakdown warning