2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 185
Information saved in
DME
Fault code
2DEC - P160B
Fault text
Power management, battery
Fault description
Powermanagement Defective
Condition for fault identification
Test condition:
is not now used
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
none
Action in service
none
Fault effect and breakdown warning
Driver information
Warning light:
No CC message
Service instruction
none
2DED
2DED - P160F
Information saved in
DME
Fault code
2DED - P160F
Fault text
Power management, closed-circuit current violation
Fault description
Powermanagement No-Load Current Error
Condition for fault identification
Test condition:
Standby current violation:
Standby current draw exceeds approved level. Standby
current is calculated only when ISD-BSD communications
are not present - vehicle in sleep mode.
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
Vehicle in sleep mode
Action in service
Conduct energy diagnosis:
Fault effect and breakdown warning