2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 46

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 46



Test condition:



Monitoring of boot software



After system start with with ignition on



Terminal condition: Terminal 15 ON



Voltage condition:



none



Condition for fault memory entry



No debounce. Fault can be reset by clearing fault memory.



However, a successful diagnostic cycle must be completed



before the fault can be deleted. This can take several



minutes.



Action in service



Flash program correct program version.



Fault effect and breakdown warning



Driver information



Warning light:



none



Service instruction



none



2AB3 - P16A1 (DME)



2AB3 - P16A1



Information saved in



DME



Fault code



2AB3 - P16A1



Fault text



DME, internal fault: checksum



Fault description



Internal Control Module Memory Check Sum Error in



Application Software



Condition for fault identification



Test condition:



Application software program monitor (development only)



Terminal condition: none



Voltage condition:



none



Condition for fault memory entry



none



Action in service



Flash program correct program version.



Fault effect and breakdown warning