Saturday, 15 June 2019

Disclaimer2000 BMW 528i (E39) 2000 BMW 528i (E39) 2000 BMW 528i (E39) Technical Service Bulletin # 612306 Date: 061001


Electrical - Battery Chager Causes Fault Codes to Set



SI B 61 23 06



October 2006



General Electrical Systems



Technical Service



This Service Information bulletin supersedes S.M. B61 204 03 dated November 2003.



SUBJECT



Battery Charger Cause Faults to be Set



528



MODEL



Vehicles with an Intelligent Battery Sensor (IBS), including E60



SITUATION



The battery charger is connected directly to the battery. If the battery is connected directly to the battery, the IBS senses current being drawn by the



vehicle electrical system, but with a battery voltage that remains constant. This causes faults to be set.



INFORMATION



When using the battery charger on a vehicle with an IBS, the battery charger must be connected to the battery terminal under the hood.