Saturday, 29 June 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 297

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 297



Or conduct the system test



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system > 10 V



Condition for fault memory entry



none



Action in service



1. Replace AKKS



Fault effect and breakdown warning



Driver information



Warning light:



no external display;



Service instruction



none



2F11 - U1130 (DME)



2F11 - U1130



Information saved in



DME



Fault code



2F11 - U1130



Fault text



Radiator blind, top



Fault description



Lost Communication With Radiator Shutter (Upper)



Condition for fault identification



Test condition:



1. AKKS must be initalized.



Operation of lower flap:



3 x open and 3 x closed



Or conduct the system test



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system > 10 V



Condition for fault memory entry



none



Action in service



1. Check voltage supply to AKKS (focus especially on GND



[PIN 2] at the valve)



2. If OK, then replace AKKS



Fault effect and breakdown warning