Friday, 28 June 2019

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 121

2019 BMW 128i Convertible (E88) L6-3.0L (N51) A L L Diagnostic Trouble Codes ( DTC ): Manufacturer Code Charts Page 121



at time of adaptation request



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system >= 10 V



Condition for fault memory entry



none



Action in service



1) Check adaptation conditions, following confirmation



proceed to terminal switch



Fault effect and breakdown warning



Driver information



Warning light:



CC status report: Reduction in engine performance!,



MIL ON



Throttle valve emergency default mode + speed governed to



1300 rpm



Service instruction



none



2CFB - P1633 (DME)



2CFB - P1633



Information saved in



DME



Fault code



2CFB - P1633



Fault text



Throttle-valve adaptation value



Fault description



Throttle Valve Adaptation Limp-Home Position Unknown



(Bank 1)



Condition for fault identification



Test condition:



Terminal change and request for adaptation



Terminal condition: Terminal 15 ON



Voltage condition:



Voltage in onboard electrical system >= 10 V



Condition for fault memory entry



none



Action in service



1) Check: Sum of throttle valve voltages must equal 5 V,



2) Perform electrical check on wires to throttle valve



sensors,



Visual inspection of plug-in terminals (on components,



wiring harness and DME),



3) Component defect improbable, replace throttle valve only



in emergency



Fault effect and breakdown warning



Driver information



Warning light:



CC status report: Reduced engine performance!,



MIL ON



EMB + rpm limit 1300 rpm