2000 BMW 328i (E46) Technical Service Bulletin # 641005 Date: 050801
A/C - IHKA Inoperative/Fuse 28 Blown
SI B 64 10 05
Heating and Air Conditioning
August 2005
Technical Service
SUBJECT
IHKA Inoperative, Fuse 28 Blown
MODEL
E46 (3 Series)
SITUATION
The customer states that the IHKA panel does not operate.
CAUSE
Fuse 28 is blown caused by shorted wiring or a seized e-box fan.
PROCEDURE
1. Check to see if Fuse 28 is blown.
2. If Fuse 28 is blown, then check wiring to e-box fan for shorting (possibly under e-box mounting screw). Repair wiring as necessary.
3. If wiring is good, check e-box fan for seizure (spins freely).
4. Replace fan if seized.
WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle Limited Warranty.