BMW 528i (E60) L6-3.0L (N52K) Technical Service Bulletin # 640305 Date: 110501


A/C - Poor Performance At Start Up Or When Idling



SI B64 03 05



Heating and Air Conditioning



May 2011



Technical Service



This Service Information bulletin supersedes SI B64 03 05 dated March 2010.



[NEW] designates changes to this revision



SUBJECT



2010 BMW 528i (E60) L6-3.0L (N52K) Page 124



Air Conditioning System Poor Performance



MODEL



E60, E61 (5 Series) with 6 cylinder engines only



SITUATION



The customer may experience one of the following conditions:



1. The air conditioning system has permanent insufficient cooling, especially during idling or while driving in heavy traffic conditions with high



outside temperature even when the system is set to "MAX" A/C.



2. No cold air from air conditioning during the first 2 minutes of operation after starting the engine. After this time the system seems to work



properly.



CAUSE



1. Compressor failure due to damaged internal control valve.



2. This is considered normal system operation. When the vehicle is parked for extended periods, liquid refrigerant can migrate into the compressor.



It may take up to 2 minutes to displace the liquid refrigerant from the compressor before starting normal operation.



PROCEDURE 1



[NEW] Refer to SI B64 04 07. Heating and Air Conditioning Symptom Diagnosis.



PROCEDURE 2



Do not replace any parts. This is considered normal operation of the system. Explain to the customer that this condition may occur if the vehicle is



parked for extended periods (greater than 8 hours). Over time liquid refrigerant can drain back into the compressor when the vehicle is parked. If the



A/C system were to function at 100% right from startup the compressor would be damaged. The system is then started up gradually to prevent this



from happening and extending the life of the compressor. Normally the system is functioning at 100% after 30-60 seconds, but in extreme conditions



it may take up to 2 minutes for the system to function at 100%.



[NEW] WARRANTY INFORMATION



This service information bulletin is intended to provide technical diagnostic and/or repair information only.



If a warranty claim results from the above repairs, it should be submitted following the regular warranty claim procedures.