Monday, 12 February 2018

BMW 328i Sedan (E90) L6-3.0L (N51) Manufacturer Code Charts 73

 

BMW 328i Sedan (E90) L6-3.0L (N51) Manufacturer Code Charts 73

2. Signal interference

3. Replace NWA sensor, transmitting inverted signal

Fault effect and breakdown warning

Driver information

Warning light:

MIL 2nd DC,

CAM operates in emergency default mode

Service instruction

none

2A12 - P2418 (DME)

2A12 - P2418

Information saved in

DME

Fault code

2A12 - P2418

Fault text

DMTL solenoid valve, activation

Fault description

Evaporative Emission System Switching Valve Control

Circuit/Open

Condition for fault identification

Test condition:

Monitoring of control activation

when solenoid is triggered

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

0.5 sec.

Action in service

1Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning

Driver information

Warning light:

MIL ON

Service instruction

none

2A12 - P2419 (DME)

2A12 - P2419

Information saved in

DME

Fault code

2A12 - P2419

Fault text

DMTL solenoid valve, activation

 