Tuesday, 14 November 2017

BMW X6 M (E71) Technical Problem # 660410 Date: 100701 Collision Avoidance - Reverse Camera Not Calibrating SI B 66 04 10 Distance Systems, Cruise Control, Remote Control

BMW X6 M (E71) Technical Problem # 660410 Date: 100701
Collision Avoidance - Reverse Camera Not Calibrating
SI B 66 04 10
Distance Systems, Cruise Control, Remote Control
July 2010
Technical Service
SUBJECT
Calibration of the Reverse Camera Does Not Work
MODEL
E70 (X5
E71 (X6)
SITUATION
Calibration of the reverse camera does not work as per the instructions in ISTA D2.20.
CAUSE
In the ISTA test plan, the wrong settings are displayed, which prevents the target values from being reached.
  Page 344
PROCEDURE
Use ISTA D2.21 or later to perform the calibration of the reverse camera. The values have been corrected.
WARRANTY INFORMATION
For information only